Technology

Prevention Before Intervention

CardioGrade is the U.S. and Mexico distributor for Integrated Medicine of the HealthSTATS BPro® Radial Pulse Wave Acquisition Device. This non-invasive, FDA-approved device uses pulse wave technology to measure Central Aortic Systolic Pressure (CASP) and radial Augmentation Index (rAI) with clinical accuracy.

The patented A-PULSE CASP® software generates a report showing how the patient’s measurements compare to specific age groups.

To speak with us directly and to purchase a device, click here.

casp computer 393x313 custom TechnologyThese measurements — CASP and rAI — identify cardiovascular health and arterial stiffness far better than standard brachial cuff blood pressure. Health professionals affirm that it gives them the ability to see and prevent cardiovascular disease before it devastates patients.

Device Description

The revolutionary, non-invasive BPro® device allows medical practitioners and researchers to acquire highly reproducible and accurate real-time arterial pulse wave data. These breakthroughs are achieved both by innovative hardware design and software algorithm of patented EVBP® technology.

With its ease of use and integrated application software package BPro® makes real-time arterial pulse wave measurements the standard of medical care for the early health management of hypertension and related illnesses.

Device Capabilities with Integrated Application Software Package

casp report2 Technology(I) A 24-hr macroscopic view of BP patterns, including blood pressure, heart rate, mean arterial pressure, and pulse pressure.

BPro® is the first device in the world that uses applanation tonometry methodology to capture 24-hr blood pressure readings. It takes the blood pressure measurement even without the wearer knowing about it.

(II) Real time microscopic arterial pulse waveform analysis.

Using the BPro® and the pulse wave analysis application software, one is able to acquire real time arterial pulse wave data and translated this waveforms into clinically diagnostic related indices.

Every clinician now has a very powerful tool for complete assessment of the status of the arterial tree of patients, including evidence-based approaches in the treatment and management of pulse wave related illnesses.

BPro® Approved by the FDA & Validated by AAMI & ESH

BPro® has been approved by the U.S. FDA and validated independently by the National Heart Centre of Singapore in compliance with the protocols set by the Association for the Advancement of Medical Instrumentation (AAMI) and European Society of Hypertension (ESH).

BPro® EVBP® Software Technology

BPro® incorporates a patented technology: Modified Applanation Tonometry, or what is known as EVBP® technology. EVBP® stands for Evidence-Based Blood Pressure. Tonometry was first used for the measurement of pressure in the eyeballs. HealthSTATS BPro® ABPM device implements the measurement at the radial artery of the wrist. (see illustration below).

For more information and to purchase a device, click here.

How It Works

The figure below shows the cross section of the wrist that the BPro® is secured to by means of a wrist strap, similar to a watch in application.

BPro-tech NEW

The sensor plunger impinges upon the radial artery over the radius bone. The patented plunger system design is hemispherical in profile, and transfers pressure forces efficiently to the internal pressure sensor and provides a safe, comfortable patient interface.

The wrist strap system is specially designed to ensure that the sensor system mounts comfortably on the radial artery position. At the same time, together with the sensor housing, it provides constant applanation to the artery without compromising the comfort of the wearer.

The strap system also takes into consideration in allowing for venous return at both the watch head and housing, and also avoiding any median nerve compression.

bprowrist 605x383 custom Technology

With the above features, a non-invasive reliable and accurate radial pulse wave is acquired.

As shown in figure above, BPro® is a watch-like device worn on the patient’s wrist. It is easy to use and mount on the wearer’s radial artery.

BPro 1-2-3-s

BPro® Features

  • Specially designed to visually reflect a watch-like monitoring device.
  • Lightweight and easy to use.
  • Specially designed mounting strap to secure BPro® device onto the wrist position.
  • Does not disturb daily activities and night sleep.
  • Delicate sensor with high accurate data acquisition capability
  • Able to monitor 24-hr blood pressure and capture real time arterial pulse waves.

For more information and to purchase a device, click here.

BPro® Specifications

Specifications Parameters
General
Model T6200 series
Display LCD, 20 mm X 20 mm 2 lines
Displayed parameters
– ABPM mode Systolic pressure in mmHg
Diastolic pressure in mmHg
Pulse rate in beats/minutes
– PWA mode Pulsation bar
Memory (For ABPM) 96 blocks of waveform readings
Reading cycle time (For ABPM) 8 to 10 seconds
Measurement range
– Blood pressure 40 to 280 mmHg
– Pulse rate 30 to 180 beats/minute
Power source 3V CR 2032 coin battery
Battery life 1 – 6 months depending on usage
Buttons Five buttons

1. Mode
2. Light
3. Forward
4. Reverse
5. BP

Operating Principles
Measurement method Modified arteries applanation tonometry
Measurement site Radial artery at the wrist (Left or Right)
Calibration
Calibration method Oscillometric, performs prior to use
Size and Weight
Size – Watch head 44mm W X 51mm L X 19mm H
Size – Sensor housing 32mm W X 38mm L X 16mm H
Weight 20 grams
Environmental
Operating conditions 10 to 40ºC, 15 to 90% relative humidity (non-condensing).

80 to 106kPa atmospheric pressure

Regulatory compliance FDA, CE, SFDA, TGA, HSA
Accessories
BP Calibrators, blood pressure cuff Regular adult, for arm circumferences 21 to 30 cm. Included with system.

Optional: Large adult, for arm circumferences from 29 to 42 cm.